TVLogic has introduced their latest firmware for the VFM-058W, which displays metadata from the Arri ALEXA camera series. Users must request the firmware from TVLogic; it cannot be downloaded directly from the website.
When requesting the firmware, you must have the serial number of the monitor you want to update. Here is the link to the RMA form to request the firmware: http://tvlogicusa.com/Support/Spt_RMA.asp?L_Code=RMA Updating the firmware on the VFM-058W is done via USB stick, but before loading the files onto the drive, you must format the drive in ExFat. Load the .rbf & .hex file onto the drive and follow the steps below to update the monitor.
- Power up the monitor. Make sure you have a fully charged battery or power supply. Firmware updates may take as long as 20 minutes.
- Insert USB drive into the monitor.
- Open Menu and select System Menu.
- At the bottom, will be the Firmware Update menu; select Yes.
- The monitor will go dark while the update is taking place. There is no access to menus during firmware update. DO NOT turn off power.
- The firmware update will take up to 15-20 minutes.
- The firmware update is complete when "no video" is displayed on lower left of screen.
- The USB can be removed. The monitor is ready to use.